HadleySFS section range
SFS sections are available in a wide range of depths and configurations to suit different structural requirements and project specifications. The right section depends on factors such as the required strength, span and application of the framing system. Within the HadleySFS Section Range, stud depths are available in the following sizes: 70mm, 120mm, 150mm, 200mm, 255mm and 305mm. This range offers flexibility when selecting the right SFS section for your project.
SFS framing system explained
An SFS framing system consists of a range of stud and track sections. Each section has a unique reference code that makes it easy to identify the required profile. The code provides information about the section’s dimensions and properties, including its depth, width, gauge and whether the section is lipped or un-lipped.
This reference system makes it easier for architects, engineers and contractors to select the right SFS sections and identify them on site. Below is an explanation of how the different section references are structured.
Stud sections (lipped sections)
Stud sections are used as the vertical components of an SFS frame. A stud section is lipped and can be identified by the letter F in the section reference.
Example: 150F5012
• 150: the section depth is 150mm.
• F: represents the HadleySFS stud section. The F indicates that the section is lipped.
• 50: the width of the section flange is 50mm.
• 12: the section gauge is 1.2mm. The final two digits indicate the thickness in tenths of a millimetre.Track Sections (un-lipped sections)
Track sections form the horizontal components of an SFS frame and are used to connect the stud sections at the top and bottom. Track sections are always un-lipped and can be identified by the letter T.
Example: 154T7020
• 154: the section depth is 154mm.
• T: represents the HadleySFS track section. This section is always un-lipped.
• 70: the width of the section flange is 70mm.
• 20: the section gauge is 2.0mm. The final two digits indicate the thickness in tenths of a millimetre.Slotted sections
In cases where slotted sections are required to deal with building deflection, “S” is included in the section reference to denote slotted.
Example: 154TS7020
• 154: the section depth is 154mm.
• T: represents the HadleySFS track section. The section is always un-lipped.
• S: indicates that the track section is slotted to accommodate movement.
• 70: the width of the section flange is 70mm.
• 20: the section gauge is 2.0mm. The final two digits indicate the thickness in tenths of a millimetre.
Why choose HadleySFS?
HadleySFS combines high-quality SFS framing systems with technical expertise and support throughout the project. From selecting the right system to technical design and installation, Hadley’s team supports you in finding the right solution for your project.
All HadleySFS framing systems comply with the relevant requirements for fire safety, acoustic and thermal performance, in accordance with the latest building regulations. System performance has been validated by independent UKAS-accredited laboratories. This includes fire ratings in accordance with BS EN 1364-1 and acoustic ratings in accordance with BS EN ISO 717-1:1997, BS EN 1991 and BS EN 1993.
Hadley’s in-house technical design experts have extensive knowledge of the construction industry, SFS framing systems and drylining applications. In addition to technical guidance and system specifications, Hadley can provide fire and acoustic test data and acoustic calculations to help you select the right steel framing system for your project.
All HadleySFS systems are also backed by the 60-year HadleySpec Performance Warranty, providing additional confidence in the performance and reliability of the system.
Benefits of our SFS framing systems
- Rapid installation: the dry building envelope can be installed quickly, allowing internal trades to start earlier.
- Reduced cost and weight: SFS can help reduce costs and structural weight compared with other construction methods.
- Less cutting on site: materials can be ordered to the required length.
- BBA certification: the systems have been independently certified.
- Technical support: Hadley provides an in-house design and detailing service.
- Insured design service: the design service is covered by Professional Indemnity (PI) insurance.
- 60-year warranty: all Hadley SFS systems are backed by the HadleySpec Performance Warranty.
SFS technical resources
Hadley provides technical resources to help you select and specify the right SFS framing system for your project. These resources include load and span tables, technical specifications and other information to support the design and specification of HadleySFS systems. For guidance on the load and span capabilities of HadleySFS sections, see the SFS Load & Span Tables.